摘    要:在小尺寸房间模型内,研究了热烟气流过顶棚开口的形式,指出在L/D(顶棚的厚度与开口直径比)较小的情况,可出现五种主要流型;并对烟气流率的计算方法作了讨论,提出的改进算法综合考虑了室内外气体的密度差和L/D的影响,在L/D=(0.01—0.6)的范围内,与实验数据符合得较好.

关 键 词:建筑火灾,顶棚开口,密度差,烟气流率

Some Discussions on the Flow Pattern and Flow Rate of Smoke through a Ceiling Opening in Enclosure Fire
Huo Ran,Li Changfeng,Liu Binghai. Some Discussions on the Flow Pattern and Flow Rate of Smoke through a Ceiling Opening in Enclosure Fire[J]. Journal of University of Science and Technology of China, 1996, 26(3): 324-328
Authors:Huo Ran  Li Changfeng  Liu Binghai
Affiliation:State Key Laboratory of Fire Science
Abstract:he flow pattern of smoke flowing through a ceiling opening is investigated in a reducedscale model, and five major Patterns are found at a relatively small L/D (ceiling length to opening diameter). The calculation of smoke flow rate is discussed too. The proposed method considered both the density difference of smoke and air, and the L/D variation are taken into consideration in the proposed method for improvement. The calculation resultS is in good agreement with the test data. It iS pointed out the effects of L/D can not be neglected in calculation.
Keywords:Building fire   Ceiling opening   Density difference   Volume flow rate.