首页 | 本学科首页   官方微博 | 高级检索  
     

A new design method for asymmetrical head gradient coils used for superconducting MRI scanner
引用本文:TANG Xin,ZU Donglin,BAO Shanglian. A new design method for asymmetrical head gradient coils used for superconducting MRI scanner[J]. 自然科学进展(英文版), 2004, 14(9): 753-757. DOI: 10.1080/10020070412331344271
作者姓名:TANG Xin  ZU Donglin  BAO Shanglian
作者单位:Institute of Heavy Ion Physics, and Beijing Key Laboratory of Medical Physics and Engineering, School of Physics, Peking University,Beijing 100871, China,Institute of Heavy Ion Physics, and Beijing Key Laboratory of Medical Physics and Engineering, School of Physics, Peking University,Beijing 100871, China,Institute of Heavy Ion Physics, and Beijing Key Laboratory of Medical Physics and Engineering, School of Physics, Peking University,Beijing 100871, China
摘    要:A novel approach of asymmetrical gradient coil design for head imaging in MRI (magnetic resonance imaging) is presented in this paper. The design is based on a modified target field method in which the stream function is introduced to replace Blaine's scheme for the length control. The transverse head coil calculated by this method has a high performance. The coil efficiency is 0.41 mT/m/A and the inductance is 512 μH. The coil has an inner diameter of 32 cm and a length of 45.8 cm. The size of the ROU (region of uniformity) is 20 cm along the transverse direction and 17 cm along the axial direction and it is close to one end of the coil. The ROU of the coil matches the ROI (region of interest) of human head very well. Compared with previous designs, our design has relatively high performance and the overlap between the ROU and the ROI is larger (the overlap percent is 95 % ).

关 键 词:MRI   head imaging   gradient coil   target field method   stream function

A new design method for asymmetrical head gradient coils used for superconducting MRI scanner
Tang Xin,ZU Donglin,Bao Shanglian. A new design method for asymmetrical head gradient coils used for superconducting MRI scanner[J]. Progress in Natural Science, 2004, 14(9): 753-757. DOI: 10.1080/10020070412331344271
Authors:Tang Xin  ZU Donglin  Bao Shanglian
Affiliation:Institute of Heavy Ion Physics, and Beijing Key Laboratory of Medical Physics and Engineering, School of Physics, Peking University,Beijing 100871, China
Abstract:A novel approach of asymmetrical gradient coil design for head imaging in MRI (magnetic resonance imaging) is presented in this paper. The design is based on a modified target field method in which the stream function is introduced to replace Blaine's scheme for the length control. The transverse head coil calculated by this method has a high performance. The coil efficiency is 0.41 mT/m/A and the inductance is 512 μH. The coil has an inner diameter of 32 cm and a length of 45.8 cm. The size of the ROU (region of uniformity) is 20 cm along the transverse direction and 17 cm along the axial direction and it is close to one end of the coil. The ROU of the coil matches the ROI (region of interest) of human head very well. Compared with previous designs, our design has relatively high performance and the overlap between the ROU and the ROI is larger (the overlap percent is 95 % ).
Keywords:MRI  head imaging  gradient coil  target field method  stream function
本文献已被 万方数据 等数据库收录!
点击此处可从《自然科学进展(英文版)》浏览原始摘要信息
点击此处可从《自然科学进展(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号