接地电阻对放电击中点影响的试验研究
引用本文:钱冠军,王晓瑜,徐先芝,汪雁.接地电阻对放电击中点影响的试验研究[J].华中科技大学学报(自然科学版),1998(9).
作者姓名:钱冠军  王晓瑜  徐先芝  汪雁
作者单位:华中理工大学电力工程系
摘    要:采用对比性试验,研究了接地电阻对火花放电击中点的影响.试验结果和观测均表明,接地电阻能抑制从接地端产生的迎面放电的发展速度和通道强度,从而使其被击中概率下降,负极性比正极性下接地电阻对火花放电击中点的影响要显著得多.

关 键 词:放电击中点  接地电阻  正极性  负极性

The Experimental Study on Ground Resistance Affecting Discharge Striking Points
Qian Guanjun,Wang Xiaoyu,Xu Xianzhi,Wang Yan.The Experimental Study on Ground Resistance Affecting Discharge Striking Points[J].JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY.NATURE SCIENCE,1998(9).
Authors:Qian Guanjun  Wang Xiaoyu  Xu Xianzhi  Wang Yan
Institution:Qian Guanjun Wang Xiaoyu Xu Xianzhi Wang Yan
Abstract:The effect of ground resistance on discharge striking points has been studied by the contrast experiments. The phenomena and results show that the ground resistance can restrain the velocity and the strength of upward discharge, which will reduce the striking probability. The effect of ground resistance with negative polarity on discharge striking point is more sensitive than with positive polarity.
Keywords:discharge striking point  ground resistance  positive polarity  negative polarity