利用聚镁试剂薄膜修饰电极测定维生素C |
| |
引用本文: | 周谷珍,鄢美姣,孙元喜. 利用聚镁试剂薄膜修饰电极测定维生素C[J]. 湖南文理学院学报(自然科学版), 2015, 0(3): 29-32. DOI: 10.3969/j.issn.1672-6146.2015.03.008 |
| |
作者姓名: | 周谷珍 鄢美姣 孙元喜 |
| |
作者单位: | 湖南文理学院化学化工学院,湖南常德,415000 |
| |
摘 要: | 利用循环伏安法研究了聚镁试剂薄膜修饰电极(PMSJE)的制备条件,详细讨论了该修饰电极对维生素C(Vc)的电催化作用。实验结果表明,在0.01 mol/L H2SO4+0.1 mol/L KNO3体系中,Vc的摩尔浓度在1.0×10-2~3.0×10-4 mol/L范围内,氧化峰电流与浓度呈良好的线性关系,检出限可达2×10-5 mol/L。8次平行样品测定结果的相对标准偏差为1.1%,样品回收率为93.6%~109.8%。
|
关 键 词: | 聚镁试剂 薄膜修饰电极 测定 维生素C |
The determination of Vitamin C using poly-magnesonl film modified eletrode |
| |
Abstract: | The preparation conditions and electrocatalsis raction on Vitamin C (Vc) of poly-magnesonl film modified electrode (PMSJE) are studied by the circulation voltammetry. In 0.01 mol/L H2SO4+ 0.1 mol/L KNO3, the concentration of Vitamin C has a good linear relations in 1.0 × 10?2~3.0 × 10?4mol/L with the oxy-peak current, detection limit reaches 2 × 10?5mol/L. The sample is tested eight times, the relative standard deviation (RSD) of which is not more than 1.1% and the recovery rate of sample is 93.6%~109.8%. |
| |
Keywords: | poly-magnesonl film modified electrode determination Vitamin C |
本文献已被 CNKI 万方数据 等数据库收录! |
|