首页 | 本学科首页   官方微博 | 高级检索  
     

螺纹槽管传热和流体阻力的数值模拟
引用本文:王星天,朱俊峰,曹亮,王世锋,全强,侯诗文. 螺纹槽管传热和流体阻力的数值模拟[J]. 科学技术与工程, 2021, 21(17): 7092-7097. DOI: 10.3969/j.issn.1671-1815.2021.17.017
作者姓名:王星天  朱俊峰  曹亮  王世锋  全强  侯诗文
作者单位:中国水利水电科学研究院牧区水利科学研究所,呼和浩特010020
基金项目:国家重点研究发展计划(2018YFE0196000);基中国水利水电科学研究院基础科学研究项目(MK2018J09)
摘    要:对螺纹槽管在恒壁温和雷诺数(Re)5000~35000范围内空气的换热性能和压降进行了数值研究.分别对25种不同几何参数的螺纹槽换热管换热性能和压降与同参数的光滑管进行了对比分析.结果表明,螺纹槽管的换热性能显著强于光滑管,同时压降也不同程度地高于光滑管;其中螺纹槽深度对换热性能和压降的影响大于螺纹槽间距,二者存在相互...

关 键 词:强化传热  螺纹槽管  压降  烟气余热回收  节能
收稿时间:2020-08-31
修稿时间:2021-03-28

Numerical investigation of heat transfer and fluid resistance in spirally fluted tubes
Wang Xingtian,Zhu Junfeng,Cao Liang,Wang Shifeng,Quan Qiang,Hou Shiwen. Numerical investigation of heat transfer and fluid resistance in spirally fluted tubes[J]. Science Technology and Engineering, 2021, 21(17): 7092-7097. DOI: 10.3969/j.issn.1671-1815.2021.17.017
Authors:Wang Xingtian  Zhu Junfeng  Cao Liang  Wang Shifeng  Quan Qiang  Hou Shiwen
Affiliation:Institute of Water Resources for Pastoral Area, Ministry of Water Resources
Abstract:In this paper, the heat transfer performance and pressure loss of air in the range of constant wall temperature and Reynolds number ranging from 5000-35000 are numerically studied. The heat transfer performance and pressure loss of spirally fluted tubes with 25 different geometric parameters were compared with smooth tubes. The results show that the heat transfer performance of the spirally fluted tube is significantly better than that of the smooth tube, and the pressure loss is also higher than that of the smooth tube in varying degrees. The influence of the depth of the flute on the heat transfer performance and pressure loss is greater than that of the flute pitch, and there is interaction between the two, showing the optimal interval principle. The maximum average Nusselt number appears at Re = 5000, geometric parameters dl / D = 0.25, pl / D = 0.5, which is 3.1 times of smooth tube. The maximum PEC value is 1.404, when Re = 5000, geometric parameters dl / D = 0.15, pl / D = 1, the heat transfer performance of the spirally fluted tube is 1.8 times than the smooth tube, and the friction factor is 2.25 times than the smooth tube. Considering the overall Reynolds number range, the optimal geometric parameters are dl / D = 0.14 to 0.18, pl / D = 0.8 to 1.2.
Keywords:Heat transfer enhancement   pressure loss   spirally fluted tube   flue gas heat recovery   energy conservation
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《科学技术与工程》浏览原始摘要信息
点击此处可从《科学技术与工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏