首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于Uranyl-Salophen-SDS体系荧光光谱法检测铀
引用本文:苏昌霖,廖力夫,郦志阳,王志梅,张迪,肖锡林.基于Uranyl-Salophen-SDS体系荧光光谱法检测铀[J].南华大学学报(自然科学版),2019,33(4):67-72, 78.
作者姓名:苏昌霖  廖力夫  郦志阳  王志梅  张迪  肖锡林
作者单位:南华大学 化学化工学院,湖南 衡阳 421001,南华大学 化学化工学院,湖南 衡阳 421001,南华大学 化学化工学院,湖南 衡阳 421001,南华大学 化学化工学院,湖南 衡阳 421001,南华大学 化学化工学院,湖南 衡阳 421001,南华大学 化学化工学院,湖南 衡阳 421001
基金项目:国家自然科学基金项目(11475079)
摘    要:铀是一种重要的自然资源,在多个领域都有广泛的用途,所以检测铀也变得越来越有意义。建立了一种操作简单,价格低廉,灵敏度高的检测方法,首先将Salophen与铀酰结合成Uranyl-Salophen配合物,接着采用十二烷基硫酸钠(SDS)表面活性剂将配合物包裹,从而达到增敏检测U(VI)的目的。优化了时间、温度、SDS剂量、pH条件,在最优条件下荧光强度与铀的浓度范围在0.005~3.5 mol/m L下呈现良好的线性关系,在实际样品中检测铀的回收率在96%~103%。

关 键 词:铀酰  十二烷基硫酸钠  增敏  荧光强度
收稿时间:2019/5/5 0:00:00

Determination of Uranium by Fluorescence Spectrophotometry in Uranyl-salophen-SDS System
SU Changlin,LIAO Lifu,LI Zhiyang,WANG Zhimei,ZHANG Di and XIAO Xilin.Determination of Uranium by Fluorescence Spectrophotometry in Uranyl-salophen-SDS System[J].Journal of Nanhua University:Science and Technology,2019,33(4):67-72, 78.
Authors:SU Changlin  LIAO Lifu  LI Zhiyang  WANG Zhimei  ZHANG Di and XIAO Xilin
Institution:School of Chemistry and Chemical Engineering,University of South China,Hengyang,Hunan 421001,China,School of Chemistry and Chemical Engineering,University of South China,Hengyang,Hunan 421001,China,School of Chemistry and Chemical Engineering,University of South China,Hengyang,Hunan 421001,China,School of Chemistry and Chemical Engineering,University of South China,Hengyang,Hunan 421001,China,School of Chemistry and Chemical Engineering,University of South China,Hengyang,Hunan 421001,China and School of Chemistry and Chemical Engineering,University of South China,Hengyang,Hunan 421001,China
Abstract:Uranium is an important natural resource and is widely used in many fields,so it is becoming more and more meaningful to detection of uranium.In this paper,a simple operation,low cost and high sensitivity detection of method was established.Firstly,the Uranyl-Salophen complex was formed by the combination of Salophe with uranyl.And then detect U(VI) effectively by adding sodium dodecyl sulfonate(SDS) to the above substances.It optimized the time,temperature,SDS concentration,pH condition.The fluorescence intensity and the range of uranium concentration showed a good linear relationship during 0.005~3.5 mol/mL under the optimal conditions.This method can be used in the detection of practical samples and the recovery rate was 96%~103%.
Keywords:uranyl  sodium dodecyl sulfate  sensibilization  fluorescence intensity
本文献已被 CNKI 等数据库收录!
点击此处可从《南华大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《南华大学学报(自然科学版)》下载免费的PDF全文