Rectifying control of wire diameter during dieless drawing by a deformation measuring method of interframe displacement
Authors:Yong He  Xue-feng Liu  Fang Qin  Jian-xin Xie
Affiliation:1. Key Laboratory for Advanced Materials Processing (Ministry of Education), University of Science and Technology Beijing, Beijing, 100083, China
Abstract:A deformation measurement method of interframe displacement was proposed in this paper. By online monitoring the shape dimensions of both the deformation zone and its adjacent zone by machine vision, the initial and terminative positions of deformation were dynamically identified during dieless drawing, and the global monitoring and online closed-loop control of the deformation zone were achieved. The dieless drawing process was systematically carried out on NiTi shape memory alloy wires. It is shown that the deformation measurement method of interframe displacement can track the axial displacement of the wires, but this cannot be achieved by traditional machine vision. The initial and terminative positions of deformation can be accurately identified by this method. The proposed rectifying control technology can effectively decrease the wire diameter fluctuation during dieless drawing, that is, the standard deviation of the wire diameter fluctuation could be decreased from 0.30 to 0.08 mm after three passes of dieless drawing, indicating that the control system has a good rectifying ability.
Keywords:
本文献已被 万方数据 SpringerLink 等数据库收录!
点击此处可从《矿物冶金与材料学报》浏览原始摘要信息
点击此处可从《矿物冶金与材料学报》下载免费的PDF全文