摘    要:论文通过对张家界变电站综合自动化系统遥信误动的情况进行现场调查,分析了目前遥信动作存在的一些问题,提出了从变电站综合自动化分站系统和主站系统多个环节避免遥信误动的处理方法.这些处理方法已在实际变电站自动化改造工程中应用,有效地降低了遥信误动概率,保证了电力系统自动化信息的准确、可靠、实时.

关 键 词:电力系统  变电站自动化  遥信  远动
文章编号:1673-9140(2007)04-0091-04
收稿时间:2007-09-06

Analysis and countermeasure of remote signals mis-operation in zhang Jiajie electric power corporation
Authors:LI Xiao-jie  XIANG Wei
Abstract:The remote signals mis-operation of substation integrated automation system in Zhangjiajie Electrie Power Company is investigated in the paper. The problems of remote control are analyzed. Some countermeasures implemented in the substation automation systems and the control center systems are also proposed. The countermeasures are applied in some reconstruction projects of substation automation. They reduce the probability of remote signals mis-operation, and guarantee the automation information precision, reliability and in real time.