首页 | 本学科首页   官方微博 | 高级检索  
     检索      

热镀锌钢板在青岛不同海水区带的腐蚀行为
引用本文:李鑫,李焰,魏绪钧.热镀锌钢板在青岛不同海水区带的腐蚀行为[J].东北大学学报(自然科学版),2007,28(8):1147-1151.
作者姓名:李鑫  李焰  魏绪钧
作者单位:1. 东北大学,材料与冶金学院,辽宁,沈阳,110004
2. 中国科学院,海洋研究所,山东,青岛,266071
基金项目:国家自然科学基金,山东省青岛市自然科学基金
摘    要:开展了热镀锌钢板在青岛不同海水区带的实海腐蚀测试,并利用电化学测试、失重腐蚀测试和扫描电镜研究了镀层的海水腐蚀行为.结果表明,由于镀锌层腐蚀电流密度大,在全浸区流动海水中快速溶解而又难以形成稳定的保护性腐蚀产物膜,耐蚀性最差;镀层在潮差区出现不同程度的生物污损,这可能给镀层带来部分保护,其腐蚀速度比全浸区明显降低;镀层在飞溅区未发生生物污损,但腐蚀速度在三个海水区带中最低,可能与其表面良好的充气条件和腐蚀产物层的阻挡作用有关.与全浸区相比,镀锌层在飞溅区和潮差区的耐蚀性分别提高了94%和37%.

关 键 词:热浸镀层  镀锌钢板  海水腐蚀  耐蚀性  全浸区  潮差区  飞溅区  
文章编号:1005-3026(2007)08-1147-05
修稿时间:2006-08-08

Corrosion Behavior of Hot-Dip Galvanized Sheet Steel in Different Seawater Zones in Qingdao
LI Xin,LI Yan,WEI Xu-jun.Corrosion Behavior of Hot-Dip Galvanized Sheet Steel in Different Seawater Zones in Qingdao[J].Journal of Northeastern University(Natural Science),2007,28(8):1147-1151.
Authors:LI Xin  LI Yan  WEI Xu-jun
Institution:(1) School of Materials and Metallurgy, Northeastern University, Shenyang 110004, China; (2) Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China
Abstract:The commercial hot-dip galvanized sheet steel was investigated for its corrosion behavior in three different seawater zones in Qingdao with electrochemical measurement, weight loss test and SEM. The results indicated that zinc coating exposed to immersion zone dissolved quickly due to high corrosion current density and being hard to form a stable protective film resulting from the corrosion itself, i.e., galvanized steel under such conditions is the poorest one in corrosion resistance. Biofouling often takes place on galvanized steel surface exposed to tidal zone, which may result in partial protection to coating surface at obviously lower corrosion rate than the coupons in immersion zone. The splash zone is the least aggressive of all the seawater zones for galvanized steel with biofouling not occurring. The lowest corrosion rate of galvanized steel in splash zone may relate to the good air ventilation condition on coating surface and the protective film resulting from the oxidation itself. In comparison to the test coupons in immersion zone, the corrosion resistance of those in tidal and splash zones increases by 37% and 94%, respectively.
Keywords:hot-dip galvanization  galvanized sheet steel  seawater corrosion  corrosion resistance  immersion zone  tidal zone  splash zone
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《东北大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《东北大学学报(自然科学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏