首页 | 本学科首页   官方微博 | 高级检索  
     检索      

氢化物发生-原子荧光光谱法测定铅锌矿中微量铋
引用本文:罗付兴,李日平.氢化物发生-原子荧光光谱法测定铅锌矿中微量铋[J].韶关学院学报,2009,30(3):74-77.
作者姓名:罗付兴  李日平
作者单位:韶关市凡口铅锌矿质量控制中心,广东韶关512325
摘    要:通过对仪器测定条件和氢化反应介质、酸度及硼氢化钾的浓度等试验条件的优化选择.建立了HG-AFS测定铅锌矿中微量铋的分析方法,并考察了方法的精密度、准确度和检出限.实验结果表明:仪器测量精密度(PSD)为1.93%,试样测量精密度(RSD)为3.04%,加标回收率为95.3%~102.1%,检出限为0.08μg/L.若以0.5g试样最后定容至50ml计算,试样的最低检出限为0.008μg/g.

关 键 词:氢化屹发生  原子荧光  微量铋

HG-AFS determination of trace bismu in lead-zinc ore
LUO Fu-xing,LI Ri-ping.HG-AFS determination of trace bismu in lead-zinc ore[J].Journal of Shaoguan University(Social Science Edition),2009,30(3):74-77.
Authors:LUO Fu-xing  LI Ri-ping
Institution:(Center of Quality Control, Fan Kou Lead Zine Mine, Shaoguan 512325, Guangdong, China)
Abstract:To optimize the choice of measure device, Hydrogenation media, acidity and concentration of potassium borohydride, and other experimental conditions. A determination and analytical methods for trace bismuth in lead-zinc by using the HG-AFS have been establish in the paper. The methods also have been inspected for its precise, accuracy and detection limit. The test results are as: precision measuring instruments (RST) was 1.93 percent, the sample measurement precision (RSD) was 3.04%, recoveries 95.3%~102.1% for the detection limit of 0.08μg/L. In terms of 0.5g sample to 50 ml final volume terms, the minimum sample detection limit of 0.008μg/L.
Keywords:hydride generation  atomic fluorescence  micro-Bi
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号