首页 | 本学科首页   官方微博 | 高级检索  
     检索      

开口永久柱模板结合方式对叠合柱力学性能影响
引用本文:周乾,张笑鑫,荀勇,吴发红,张亚仿.开口永久柱模板结合方式对叠合柱力学性能影响[J].科学技术与工程,2020,20(10):4112-4118.
作者姓名:周乾  张笑鑫  荀勇  吴发红  张亚仿
作者单位:盐城工学院土木工程学院,盐城224051;盐城市房产管理局,盐城224002
基金项目:国家自然科学(51478408);盐城市国家可持续发展专项引导(2014-15)
摘    要:为研究开口预制柱模板结合方式对混凝土柱力学性能的影响,使用带肋纤维混凝土预制模板制作了不同拼接方式和不同接缝方式的3类、12种、24根混凝土短柱进行抗压性能试验,并与同期制作的同规格、同配筋、同配比的2根普通柱进行对比,结果表明,使用预制模板的混凝土柱的抗压能力均高于普通柱,其中,同时使用铅丝及环氧树脂接缝的错缝拼接整块模板柱的开裂荷载和极限荷载分别比普通柱高59.04%和62.98%。不同模板拼接方式试件的承载力由大到小的顺序是错缝整块模板试件、对缝整块模板试件、错缝分块模板试件;不同模板接缝方式试件的承载能力由大到小顺序是铅丝环氧树脂接缝试件、环氧树脂接缝试件、铅丝接缝试件、干接缝试件。研究成果可为该种模板推广应用提供依据。

关 键 词:开口永久性柱模板  结合方式  叠合柱  力学性能  影响研究
收稿时间:2019/7/17 0:00:00
修稿时间:2020/1/5 0:00:00

Influence on the mechanical property of laminated columns for the combining mode of open permanent column framework
Zhou Qian,Zhang Xiaoxin,Xun Yong,Wu Fahong,Zhang Yafang.Influence on the mechanical property of laminated columns for the combining mode of open permanent column framework[J].Science Technology and Engineering,2020,20(10):4112-4118.
Authors:Zhou Qian  Zhang Xiaoxin  Xun Yong  Wu Fahong  Zhang Yafang
Institution:School of Civil Engineering,Yancheng Institute of Technology,School of Civil Engineering,Yancheng Institute of Technology,School of Civil Engineering,Yancheng Institute of Technology,School of Civil Engineering,Yancheng Institute of Technology,Yancheng City Housing Authority
Abstract:In order to study the influence on the mechanical property of laminated columns for the combining mode of open permanent column framework,24 short columns were fabricated with ribbed fiber reinforced concrete prefabricated formwork, by three kinds of splicing and twelve types of joint, and compared the mechanical property with 2 original sample, which was made in the same period with the same specification, reinforcement and ratio, by the compression test. The compressive capacity of concrete columns with prefabricated formwork was higher than that of ordinary columns. The cracking load and ultimate load of the specimens, which were made by lead wire and epoxy resin and jointed by staggered joints, were 59.04% and 62.98% higher than that of ordinary columns. The order of template splicing for bearing capacity was the whole formwork with stagger seam, the whole formwork with butt seam and the partitioned formwork with staggered seam. The order of joint type for bearing capacity was the joint of lead wire and epoxy resin, the joint of epoxy resin, the joint of lead wire and the dry joint. The results can provide a basis for the application of template.
Keywords:Open Permanent Column Framework  Combining mode  Laminated column  mechanical property  Impact study