首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于单壁碳纳米管修饰电极测定贝诺酯片剂中贝诺酯的含量
引用本文:孔粉英,吕遥,李金燕,陆燕,王伟.基于单壁碳纳米管修饰电极测定贝诺酯片剂中贝诺酯的含量[J].盐城工学院学报(自然科学版),2015,28(4):1-5.
作者姓名:孔粉英  吕遥  李金燕  陆燕  王伟
作者单位:盐城工学院 化学化工学院, 江苏 盐城 224051;上海红双喜有限公司, 上海 200070;盐城工学院 化学化工学院, 江苏 盐城 224051;盐城工学院 化学化工学院, 江苏 盐城 224051;盐城工学院 化学化工学院, 江苏 盐城 224051
基金项目:浙江省哲学社会科学重点研究基地项目(江南文化研究中心)(15JDJN02YB)
摘    要:运用循环伏安法研究了贝诺酯在单壁碳纳米管修饰电极上的电化学行为。在B-R缓冲溶液(pH5.0)中,贝诺酯于1.10V(vs.SCE)电位处有一个峰形很好的氧化峰。与裸玻碳电极相比,贝诺酯在修饰电极上的电位正移了约30mV,峰电流增加了近5倍。在最佳的实验条件下,贝诺酯的氧化峰电流与其浓度(2.8×10_(-6)~1.4×10~(-4)mol/L)呈现出良好的线性关系,检出限为4.8×10~(-7)mol/L。该方法用于实际样品贝诺酯片剂的检测中,结果令人满意。

关 键 词:单壁碳纳米管  贝诺酯  化学修饰电极  电化学测定
收稿时间:2015/9/12 0:00:00

Determination of Benorilate in Benorilate Tablets by Single-wall Carbon Nanotube-modified Electrode
KONG Fenying,LÜ Yao,LI Jinyan,LU Yan and WANG Wei.Determination of Benorilate in Benorilate Tablets by Single-wall Carbon Nanotube-modified Electrode[J].Journal of Yancheng Institute of Technology(Natural Science Edition),2015,28(4):1-5.
Authors:KONG Fenying  LÜ Yao  LI Jinyan  LU Yan and WANG Wei
Institution:School of Chemistry and Chemical Engineering, Yancheng Institute of Technology, Yancheng Jiangsu 224051, China;Shanghai Double Happiness Co., Ltd, Shanghai 200070, China;School of Chemistry and Chemical Engineering, Yancheng Institute of Technology, Yancheng Jiangsu 224051, China;School of Chemistry and Chemical Engineering, Yancheng Institute of Technology, Yancheng Jiangsu 224051, China;School of Chemistry and Chemical Engineering, Yancheng Institute of Technology, Yancheng Jiangsu 224051, China
Abstract:The electrochemical behaviors of benorilate at single-wall carbon nanotabes(SWNTs)-modified glassy carbon electrode(GCE)have been investigated by cyclic voltammetry. At the SWNTs-modified GCE, benorilate yields a well-defined oxidation peak at 1. 10 V(vs. SCE)in a Britton-Robinson(B-R)buffer solution(pH 5. 0). Compared with the bare GCE, the peak potential shifted positively about 30 mV, and the peak current increased 5 times. Under the optimal conditions, the oxidation peak current of benorilate is linear with its concentration in the range of 2. 8×10-6~1. 4×10-4 mol/L, and the detection limit is 4. 8×10-7 mol/L. The proposed method has been applied to the determination of benorilate in drug tablets, and the results are satisfied.
Keywords:Single-wall carbon nanotube  Benorilate  Chemically modified electrode  Electrochemical determination
本文献已被 CNKI 等数据库收录!
点击此处可从《盐城工学院学报(自然科学版)》浏览原始摘要信息
点击此处可从《盐城工学院学报(自然科学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号