首页 | 本学科首页   官方微博 | 高级检索  
     检索      

常规氯化消毒工艺中典型消毒副产物生成的数学模型
引用本文:黄辉,周卫华,程志鹏,李倩,费相琴,徐继明.常规氯化消毒工艺中典型消毒副产物生成的数学模型[J].淮阴师范学院学报(自然科学版),2013(3):243-247.
作者姓名:黄辉  周卫华  程志鹏  李倩  费相琴  徐继明
作者单位:[1]淮阴师范学院化学化工学院江苏省生物质能与酶技术重点实验室,江苏淮安223300 [2]淮安市环境监测中心站,江苏淮安223001 [3]淮安自来水有限公司,江苏淮安223002
基金项目:淮安市科技支撑计划项目(HAS2010003);2011年江苏省大学生实践创新训练计划项目
摘    要:快速有效监控饮用水中消毒副产物的生成,是饮用水安全管理中的重要基础性工作.基于供水企业常规氯化消毒工艺过程,采用均匀试验设计,研究了水源地源水UV254值、氨氮含量、加氯量和pH值等关键因素对典型消毒副产物三卤甲烷(THMs)和卤乙酸(HAAs)生成的影响,并以SPSS统计软件对数据进行了线性和非线性拟合.结果表明:线性模型能较好地描述THMs和HAAs的生成(相关度均大于0.9),而非线性模型中二者的相关度分别为0.924和0.883;考虑各因素交互作用下,THMs和HAAs生成的线性模型的相关度均为1,进一步改善了拟合效果.建立的快速预测上述消毒副产物生成的新方法,可为完善检测条件制约下饮用水安全风险管理提供理论依据.

关 键 词:氯化消毒  消毒副产物  数学模型  均匀设计

Mathematical Model for the Formation of Typical Disinfection by-Products during Conventional Chlorination Process
HUANG Hui,ZHOU Wei-hua,CHENG Zhi-peng,LI Qian,FEI Xiang-qin,XU Ji-ming.Mathematical Model for the Formation of Typical Disinfection by-Products during Conventional Chlorination Process[J].Journal of Huaiyin Teachers College(Natrual Science Edition),2013(3):243-247.
Authors:HUANG Hui  ZHOU Wei-hua  CHENG Zhi-peng  LI Qian  FEI Xiang-qin  XU Ji-ming
Institution:1. School of Chemistry and Chemical Engineering of Huaiyin Normal University, Jiangsu Key Laboratory for Biomass based Energy and Enzyme Technology, Huaian Jiangsu 223300, China) (2. Huaian Enviromnental Monitoring Central Station, Huaian Jiangsu 223001, China) (3.Huaian Water Co., Ltd., Huaian Jiangsu 223002, China)
Abstract:Rapid and effective monitoring of the formation of disinfection by-products is critically fundamental forsecurity management of drinking water .On the basis of conventional chlorination process in waterworks ,influenc-es of four key factors ,i .e .value of UV254 and ammonia nitrogen of the raw water ,chlorine dosage andpHvalue ,on the formation of typical disinfection by-products-trihalomethanes (THMs ) and haloacetic acids (HAAs ) ,were inves-tigated by employing uniform design method ,and linear and nonlinear fitting for the data were achieved by utiliza-tion of the statistical software-SPSS .Results showed that linear modelgot a good fitting for THMs and HAAs genera-tion with the correlation coefficients both greater than 0.9 ,while correlation coefficientsof nonlinear model for the above twowere 0.924 and 0.883 ,respectively .Moreover ,correlation coefficientsof linear model for THMs and HAAs generation were both 1 in consideration of the interactions between various factors ,which further improved the fitting effects .The new approach forrapid prediction of THMs and HAAsgeneration proposed in this study ,may provides a theoretical basis for improvingrisk management of drinking watersecurity under detection-restricted conditions .
Keywords:chlorination disinfection  disinfection by-products  mathematical model  uniformdesign
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号