摘    要:高值电阻可用冲击法测量 ,也可用放电法测量 ,但这两种方法都需要比较高级的仪器 ,且测量均比较复杂 ,尤其在实验仪器比较缺乏又需要测量高阻时 ,用检流计测量高阻就显得既方便又实用。本文旨在指出一种测高阻的新方法——检流计法

关 键 词:检流计  高值电阻  临界状态
文章编号:1007-533(2001)030054-02
修稿时间:2001年1月8日

The measurement of high resistance with sensitine galvanometer
QI,Guo,quan.The measurement of high resistance with sensitine galvanometer[J].Journal of Bohai University:Natural Science Edition,2001,22(3):54-55.
Authors:QI  Guo  quan
Abstract:It is well Rnown that high resistance can be measured with shock method ,also with discharge wethod ,But the two method need more superion instrument and are more complex. It is very convenient and practicable that high resistance is measured with sensitive galvanometer ,especiauy when instrument is few and necessary .The paper will study a kind of new method of high resistance measured,i.e. sensitive galvanometer method.