首页 | 本学科首页   官方微博 | 高级检索  
     检索      

热电热泵在非设计工况条件下的性能分析
引用本文:张泠,卢豪,刘忠兵.热电热泵在非设计工况条件下的性能分析[J].科技导报(北京),2014,32(3):62-66.
作者姓名:张泠  卢豪  刘忠兵
作者单位:湖南大学土木工程学院, 长沙 410082
基金项目:国家自然科学基金项目(51178170)
摘    要: 采用直流电源模拟太阳能电池板输出不稳定电压驱动热电热泵工作,通过实验测试研究了在连续长时间工作、电压跳跃变化和极限电压工况下,热电热泵冷端温度Tc、热端温度Th、冷热端温差Td的变化对其制冷/制热的性能系数(COP)的影响。结果表明,在适宜的电压范围内,热电热泵的制冷速度快、工作性能稳定且能够长时间连续工作,而制热效果明显优于制冷效果,制热效率(Eh)平均高于制冷效率(Ec)约0.8;热电热泵的最佳工作电压区间为2~4 V,此时的冷端温度低、制冷量大、COP 值在理想范围(Ec=0.87~1.89,Eh=1.75~2.75);随着工作电压增高,热电热泵的冷热端温差增大,COP 值减小,当电压大于8V 后,冷热端温差大于45℃,COP 值降至最小,工作性能较差。

关 键 词:热电热泵    非设计工况    冷热端温差    性能系数

Analysis on Performance of the Thermoelectric Heat Pump under Off-design Conditions
ZHANG Ling,LU Hao,LIU Zhongbing.Analysis on Performance of the Thermoelectric Heat Pump under Off-design Conditions[J].Science & Technology Review,2014,32(3):62-66.
Authors:ZHANG Ling  LU Hao  LIU Zhongbing
Institution:College of Civil Engineering, Hunan University, Changsha 410082, China
Abstract:In the photovoltaic and thermoelectric system, the output voltage and current of the solar panels constantly changed with solar irradiance, resulting in the thermoelectric heat pump working under off-design conditions for a long time. To test the performance stability and affordability of the thermoelectric heat pump under off-design conditions, a DC power device replacing the solar panels was used to output unstable current to drive the thermoelectric heat pump. Under three different off-design conditions including continuously working, voltage jumping and limiting voltage, the mutual relation between hot side temperature Th, cold side temperature Tc, temperature difference Td, COP, cooling (heating) capacity and operating voltage were analysed. The results showed that the thermoelectric heat pump refrigerated fast, and it could remain stable. Its heating efficiency was about 0.8 higher than cooling efficiency which indicated that the effect of heating was obviously better than cooling. With the increasing of operating voltage, the temperature difference became greater, but the COP smaller. In addition, the best operating voltage of the thermoelectric heat pump should be between 2 V and 4 V and the effect of heat dissipation had a great influence on the cooling and heating performance of the thermoelectric heat pump.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《科技导报(北京)》浏览原始摘要信息
点击此处可从《科技导报(北京)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏