Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens
Authors:LIU Zhong-bing  ZHANG Ling  YANG Zhang  XU Ming  HAN Tian-he
Abstract:A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was pre-sented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides be-comes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller eoeffieient of performance.Under an exhaust temperature of 36℃,the coefficient of performance decreases from 1.66 tO 1.22 when the temperature of water increases from 28℃to 46℃with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of ther-moelectric heat pump water heater is more coefficient.
Keywords:thermoelectric heat pump  kitchens exhaust  water heater  coefficient of performance