作者单位:上海理工大学 能源与动力工程学院, 上海 200093;上海理工大学 能源与动力工程学院, 上海 200093;上海理工大学 能源与动力工程学院, 上海 200093;上海理工大学 能源与动力工程学院, 上海 200093;镇海石化建安工程有限公司, 宁波 315200
摘    要:分析了折流板换热器换热管泄漏的原因,并提出了改造方案.采用杆式折流替代板式折流,不仅解决了换热管束由于剧烈振动而导致的泄漏问题,而且换热器的总传热系数提高了34%,壳程阻力损失减小了23%,达到了良好的改造效果.

关 键 词:折流板  折流杆  管束振动  管束泄漏  换热性能
收稿时间:2013/3/30 0:00:00

Application Analysis of Rod Baffle Heat Exchanger
LIN You-bin,YU Hong-ling,YANG Shi-jie,CHEN Meng-jie and ZHANG Xian-an.Application Analysis of Rod Baffle Heat Exchanger[J].Journal of University of Shanghai For Science and Technology,2013,35(6):596-598.
Authors:LIN You-bin  YU Hong-ling  YANG Shi-jie  CHEN Meng-jie and ZHANG Xian-an
Institution:School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;Zhenhai Petrochemical Installation Engineering Co Ltd, Ningbo 315200, China
Abstract:The plate baffle heat exchanger in some petrochemical plant has often suffered from pipe leak.The reason of the pipe leak was analysed in detail and a transformation plan of replacing plate baffle with rod baffle was proposed.This reform not only solves the problem of pipe leak caused by severe vibration,but also increases the heat transfer coefficient by 34%,and reduces shell flow resistance by 23%.It's proved that the transformation achieves a good effect.
Keywords:plate baffle  rod baffle  pipe vibration  pipe leak  heat transfer performance