首页 | 本学科首页   官方微博 | 高级检索  
     检索      

生物秸秆不燃板房安全防火间距试验
引用本文:王厚华,季文慧,宋晓勇,李伟.生物秸秆不燃板房安全防火间距试验[J].同济大学学报(自然科学版),2018,46(12):1653-1658.
作者姓名:王厚华  季文慧  宋晓勇  李伟
作者单位:重庆大学 城市建设与环境工程学院,重庆 400045,重庆大学 城市建设与环境工程学院,重庆 400045,四川省消防总队防火部,四川 成都 610036,威特龙消防安全集团股份公司,四川 成都 611730
基金项目:国家自然科学基金项目(51578086)
摘    要:对新型生物秸秆不燃板材搭建的活动板房进行了全尺寸火灾试验.通过测量板房室内外的温度数据及室外不同距离处的热辐射强度数据,分析生物秸秆不燃板房的火灾蔓延特性.通过回归分析建立生物秸秆不燃板房的室外最大热辐射强度与距离的函数关系式,确定生物秸秆不燃板房的安全防火间距.结果表明,秸秆防火板材的阻燃性能对于抑制火灾蔓延有重要作用;采用生物秸秆不燃材料的活动板房,临栋的安全防火间距建议为2.34m;对于极端大风天气,生物秸秆不燃板房临栋的安全防火间距建议为2.51m.

关 键 词:活动板房    防灾    防火间距    秸秆
收稿时间:2018/1/28 0:00:00
修稿时间:2018/10/14 0:00:00

Full-Scale Experimental Evaluation of Fire Safety Distance of Straw Fireproofing Houses
WANG Houhu,JI Wenhui,SONG Xiaoyong and LI Wei.Full-Scale Experimental Evaluation of Fire Safety Distance of Straw Fireproofing Houses[J].Journal of Tongji University(Natural Science),2018,46(12):1653-1658.
Authors:WANG Houhu  JI Wenhui  SONG Xiaoyong and LI Wei
Institution:Faculty of Urban Construction and Environment Engineering, Chongqing University, Chongqing 400045, China,Faculty of Urban Construction and Environment Engineering, Chongqing University, Chongqing 400045, China,Sichuan General Fire Brigade, Chengdu 610036, China and Vitalong Fire Safety Group Co., Ltd., Chengdu 611731, China
Abstract:Full-scale fire experiments were conducted to study the fire safety distance of novel straw fireproofing houses. Room temperatures, ambient temperatures and thermal radiation intensities were measured to analyze the behavior of straw fireproofing houses during the fire. The formula for the maximum outdoor thermal radiation intensities of straw fireproofing house at various distances was obtained by regression analysis, and this equation could be used to calculate the fire safety distance. It is found that the fire spread is significantly restricted by using straw fireproofing material. For the straw fireproofing houses, the fire safety distance is suggested to be 2.34 m. Furthermore, for the straw fireproofing houses under severe weather conditions with strong wind, the fire safety distance is suggested to be 2.51 m.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《同济大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《同济大学学报(自然科学版)》下载免费的PDF全文