首页 | 本学科首页   官方微博 | 高级检索  
     检索      

单台引风机故障跳闸后的运行方式优化
引用本文:田勇前.单台引风机故障跳闸后的运行方式优化[J].山西科技,2013,28(5):111-113.
作者姓名:田勇前
作者单位:大唐阳城发电有限责任公司,山西晋城,048102
摘    要:介绍了某发电有限责任公司600 MW亚临界机组正常运行中单台引风机故障跳闸后的处理过程,重点论述了在该台引风机检修期间,对机组的运行方式进行的优化,即以一台引风机接带两侧风烟系统的运行方式,保证机组的安全稳定运行。

关 键 词:引风机  故障跳闸  运行方式优化

The optimization of the Operation Mode of Single Induced Draft Fan after Fault Tripping
TIAN Yongqian.The optimization of the Operation Mode of Single Induced Draft Fan after Fault Tripping[J].Shanxi Science and Technology,2013,28(5):111-113.
Authors:TIAN Yongqian
Institution:TIAN Yongqian
Abstract:This paper introduces the treating process of single induced draft fan’s fault tripping in the normal operation of 600 MW subcritical unit in a certain Power Generation Co,Ltd.,focusing on the optimization of the operation mode of the unit during overhaul of the induced draft fan,which is to connect and drive the air and gas systems on both sides by using one induced draft fan to guarantee the safe and stable operation of the unit.
Keywords:induced draft  fault tripping  optimization of operation mode