作者单位:浙江省电力公司紧水滩水力发电厂,浙江,丽水,323000
摘    要:本文主要对浙江省电力公司紧水滩水力发电厂机组定子硅钢片滑出的原因进行了分析,提出了在定子铁芯下部加装挡风板的解决方案,并于2010年3月在6号机大修期间付诸实施。通过七个月的运行数据分析,证明处理方案的效果显著。

关 键 词:定子故障  硅钢片滑出  受力分析  温度分析

Analysis on the Stator Fault of Jinshuitan Power Station
TANG Jian-xun.Analysis on the Stator Fault of Jinshuitan Power Station[J].Science and Technology of West China,2011,10(5):27-28,24.
Authors:TANG Jian-xun
Institution:TANG Jian-xun(Zhejiang Electric Power Company hydroelectric plant Jinshuitan,Lishui,Zhejiang 323000)
Abstract:This paper focused on the cause of silicon steel sliding out of the stator.The installation of a wind deflector in the lower part of the stator core was made to solve the problem.After seven months operation,it was proved that the solution was significantly benefit.