燃煤电厂电除尘PM10和PM2.5的排放控制VII:以2×600 MW机组为例分析讨论电除尘选型和改造
引用本文:梁志宏,李栓宝,陈俊峰,张金海,陈宝瑞,薛祥忠,王仕龙,闫克平.燃煤电厂电除尘PM10和PM2.5的排放控制VII:以2×600 MW机组为例分析讨论电除尘选型和改造[J].科技导报(北京),2016,34(5):84-88.
作者姓名:梁志宏  李栓宝  陈俊峰  张金海  陈宝瑞  薛祥忠  王仕龙  闫克平
作者单位:1. 神华国能王曲电厂, 潞城 047500;
2. 神华国能集团有限公司, 北京 100033;
3. 浙江大学生物质化工教育部重点实验室, 杭州 310027
基金项目:国家高技术研究发展计划(863计划)项目(2013AA065000);浙江省重点科技创新团队计划(2013TD07)
摘    要: 分析了2×600 MW机组所配套的两台双室五电场电除尘器(ESP)的设计、选型和改造。每台电除尘配套20台高压电源、一台炉配40台高压电源,改造工作不仅包括更换原80台单相电源为80台三相电源,而且将第一和第二电场的极板、极线及振打系统全部做了更换,改造后电除尘出口PM10和PM2.5(粒径分别低于10 μm和2.5 μm的颗粒物)的排放分别低于15 mg·Nm-3和1.0 mg·Nm-3,PM2.5占PM10的比例在6.5%~7.5%,与改造前比较PM2.5下降了95%以上。

关 键 词:电除尘  细颗粒物  三相电源  
收稿时间:2015-05-27

PM10 and PM2.5 emission control by electrostatic precipitator (ESP) for coal-fired power plants VII: ESP sizing and refitting with 2×600 MW boilers
LIANG Zhihong,LI Shuanbao,CHEN Junfeng,ZHANG Jinhai,CHEN Baorui,XUE Xiangzhong,WANG Shilong,YAN Keping.PM10 and PM2.5 emission control by electrostatic precipitator (ESP) for coal-fired power plants VII: ESP sizing and refitting with 2×600 MW boilers[J].Science & Technology Review,2016,34(5):84-88.
Authors:LIANG Zhihong  LI Shuanbao  CHEN Junfeng  ZHANG Jinhai  CHEN Baorui  XUE Xiangzhong  WANG Shilong  YAN Keping
Institution:1. Wangqu Power Plant, Shenhua Guoneng Energy Group Corporation Limited, Lucheng 047500, China;
2. Shenhua Guoneng Energy Group Corporation Limited, Beijing 100033, China;
3. Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang University, Hangzhou 310027, China
Abstract:This paper discusses electrostatic precipitator (ESP) sizing,refitting and upgrading with 2×600 MW coal-fired boilers. Each boiler is equipped with two five-fields ESPs and 40 high-voltage (HV) power sources. Upgrading the HV power source refers to replacing the 80 single-phase HV sources by using 80 three-phase HV sources. Refitting ESP mainly includes changing both HV and collection electrodes and their rapping systems of the first and second electrical fields. PM10 and PM2.5 emission concentrations at ESP outlets drop below 15 mg·Nm-3 and 1.0 mg·Nm-3, respectively. The PM2.5 to PM10 ratio is around 6.5%~7.5%. In comparison with previous emission, PM2.5 concentration drops down by more than 95%.
Keywords:electrostatic precipitation  PM2  5  three-phase T/R power source  