首页 | 本学科首页   官方微博 | 高级检索  
     检索      

燃煤电厂电除尘PM10和PM2.5的排放控制I:电除尘选型及工业应用
引用本文:王仕龙,陈英,韩平,张国庆,郑钦臻,沈欣军,李树然,闫克平.燃煤电厂电除尘PM10和PM2.5的排放控制I:电除尘选型及工业应用[J].科技导报(北京),2014,32(33):23-33.
作者姓名:王仕龙  陈英  韩平  张国庆  郑钦臻  沈欣军  李树然  闫克平
作者单位:1. 神华国能集团有限公司, 北京 100033;
2. 天津大港发电厂, 天津 300272;
3. 浙江大学生物质化工教育部重点实验室, 杭州 310027
基金项目:国家高技术研究发展计划(863计划)项目(2013AA065000);浙江省重点科技创新团队计划项目(2013TD07)
摘    要: 针对电除尘细颗粒物(PM2.5)排放控制,提出利用电除尘指数指导电除尘本体和电源设计选型技术的原理和方法,并介绍电除尘改造的应用案例.通过优化电除尘指数、采用三相高压电源开展电除尘改造和选型.通过电除尘和脱硫塔除雾器的同步改造,可以实现烟囱出口颗粒物排放浓度低于5 mg/m3,同时,PM2.5 (直径2.5 μm 以下的颗粒物)排放浓度低于2.5 mg/m3.示范工程还表明当电除尘器出口PM10(直径10 μm 以下的颗粒物)排放在6~30 mg/m3时,PM2.5占PM10比例为6%至20%;当PM10排放在5~15 mg/m3时,PM2.5排放可低于2.5 mg/m3.

关 键 词:电除尘  细颗粒物  电除尘指数  三相电源  
收稿时间:2014-07-17

PM10 and PM2.5 Emission Control by Electrostatic Precipitator (ESP) for Coal-fired Power Plants I: ESP Sizing and Applications
WANG Shilong,CHEN Ying,HAN Ping,ZHANG Guoqing,ZHENG Qinzhen,SHEN Xinjun,LI Shuran,YAN Keping.PM10 and PM2.5 Emission Control by Electrostatic Precipitator (ESP) for Coal-fired Power Plants I: ESP Sizing and Applications[J].Science & Technology Review,2014,32(33):23-33.
Authors:WANG Shilong  CHEN Ying  HAN Ping  ZHANG Guoqing  ZHENG Qinzhen  SHEN Xinjun  LI Shuran  YAN Keping
Institution:1. Shenhua Guoneng Energy Group Corporation Limited, Beijing 100033, China;
2. Tianjin Dagang Power Plant, Tianjin 300272, China;
3. Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang University, Hangzhou 310027, China
Abstract:This paper discusses electrostatic precipitation for fine particle emission control. According to the so-called electrostatic precipitator (ESP) index, a novel ESP sizing method is presented for both mechanical and electrical specifications. By using threephase rectifier transformer power sources, ESPs give very high collection for fine particle emission control. The ratio of PM2.5 over PM10 is between 6% and 20%. When PM10 emission is around 5-15 mg/m3, PM2.5 is below 2.5 mg/m3. By upgrading ESP and flue gas desulfurization (FGD), particle emissions can be reduced to below 5 mg/m3, and PM2.5 below 2.5 mg/m3.
Keywords:electrostatic precipitation  PM2  5  electrostatic precipitator index  three-phase T/R power source  
点击此处可从《科技导报(北京)》浏览原始摘要信息
点击此处可从《科技导报(北京)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏