改善矢量网络分析仪的长电缆测量精度
引用本文:吕朋尧.改善矢量网络分析仪的长电缆测量精度[J].科技信息,2011(1):I0117-I0117,I0126.
作者姓名:吕朋尧
作者单位:电子测试技术重点实验室,山东青岛266555
摘    要:在使用矢量网络分析仪(VNA)进行长电缆测量中,由于在电缆上的时间延迟会引入测量误差。本文通过分析VNA测量原理讨论了测量误差来源,并针对不同使用情况提出了改善测量精度的解决方法。

关 键 词:电长度  延迟  中频带宽

Improve the Measurement Accuracy of Long Cable Using Vector Network Analyzer
LV Peng-yao.Improve the Measurement Accuracy of Long Cable Using Vector Network Analyzer[J].Science,2011(1):I0117-I0117,I0126.
Authors:LV Peng-yao
Institution:LV Peng-yao (Science and Technology on Electronic Test & Measurement Laboratory,Qingdao Shandong, 266555)
Abstract:Measurement errors will be caused because of the time delay on the cable when you measure a long cable with the Vector Network Analyzer. In the paper we discuss the sources of measurement errors by analyzing the principle of VNA, solutions to increase measurement accuracy in different applieations is also given.
Keywords:Electrical length  Delay  IF Bandwidth