摘    要:研究应用基体改进剂、石墨管镧涂层和L'vov平台对岩石中铅测定时基体干扰消除的效果。结果表明,用NH_1H_2PO_4和Mg(NO_3)_2作为基体改进剂,联合运用L'vov平台,对消除岩石中的基体干扰效果最好,可达到溶样后直接测定的要求。

关 键 词:石墨炉  基体改进剂  L'vov平台  碳化物涂层

Selection of Ways to Reducing Matrix Interference in the Determination of Pb in Rocks by GFAAS
Li Binxian Zhang Xun Zhang Xiaoming.Selection of Ways to Reducing Matrix Interference in the Determination of Pb in Rocks by GFAAS[J].Journal of University of Science and Technology of China,1993,23(3):325-328.
Authors:Li Binxian Zhang Xun Zhang Xiaoming
Institution:Department of Barth and Space Science
Abstract:The effects of matrix modifiers, graphite tube La Coating and L'vov platform on the determination of Pb in rocks by GFAAS are compared. The results show that the use of ammonium dihydrogen-phosphate and magnesium nitrate as matrix modifiere, thogether with the L'vov platform works best for reducing matrix interference, and measurement is obtained in this way right after sample dissolution.