首页 | 本学科首页   官方微博 | 高级检索  
     

采用出水管差压测流法监测泵站的单机流量
引用本文:范振江. 采用出水管差压测流法监测泵站的单机流量[J]. 西安理工大学学报, 1986, 0(1)
作者姓名:范振江
作者单位:陕西机械学院水利水电工程系
摘    要:本文阐述了出水管差压测流法的原理、装置形式、仪表选择和计算方法;论证了本测流法的优缺点及其适用条件。本测流法主要用于中、低扬程的离心泵站和混流泵站在运行中监测单机流量。

关 键 词:离心泵站  混流泵站  中低扬程  单泵流量  差压  测流

MONITORING UNIT DISCHARGE OF THE PUMP STATION USING DIFERENTIAL PRESSURE METHOD OF MEASURING FLOWRATE AT THE OUTLET PIPE
Fan Zhenjiang. MONITORING UNIT DISCHARGE OF THE PUMP STATION USING DIFERENTIAL PRESSURE METHOD OF MEASURING FLOWRATE AT THE OUTLET PIPE[J]. Journal of Xi'an University of Technology, 1986, 0(1)
Authors:Fan Zhenjiang
Affiliation:Fan Zhenjiang
Abstract:In this paper, the theory, the type of testing device, the choice of apparatus and method of computation accordance with the diferential pressure method of measuring flowrate at the outlet pipe are presented. The advantages and disadvantages of the method as well as the suitable conditions of using this method are discussed. This method could be applied to monitoring unit dischatge of middle and low lift centrifugal pump station and mixed flow pump station.
Keywords:Centrifugal pump station   mixed flow pump station   middle and low lift   unit discharge of pump   differential pressure   measuring flowrate
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号