首页 | 本学科首页   官方微博 | 高级检索  
     检索      

300MW机组直流锅炉调峰运行水冷壁安全性分析
引用本文:唐虹,杨瑞昌,鲁钟琪,施德强,冯俊凯.300MW机组直流锅炉调峰运行水冷壁安全性分析[J].清华大学学报(自然科学版),1997(2).
作者姓名:唐虹  杨瑞昌  鲁钟琪  施德强  冯俊凯
作者单位:清华大学热能工程系
摘    要:用计算机辅助计算方法,以国产300MW机组UP直流锅炉水冷壁为对象,在机组调峰运行过程中炉内火焰中心发生偏斜的非正常工况的热负荷分布情况下,对300MW、260MW、240MW和210MW的不同机组负荷,计算水冷壁各管屏内工质的水力偏差和热偏差。并据此计算水冷壁管内工质的传热特性和管壁金属温度,以确定水冷壁发生爆管事故的条件。通过计算得出了不同机组负荷下所能允许的最大炉内火焰中心偏斜系数,为提出防止发生爆管事故的措施和机组的安全运行分析提供了根据

关 键 词:直流锅炉  调峰  水冷壁爆管  分析

Safety analysis of operation of water walls of a 300 MW once through boiler in peak load operation
Tang Hong,Yang Ruichang,Lu Zhongqi,Shi Deqiang,Feng Junkai.Safety analysis of operation of water walls of a 300 MW once through boiler in peak load operation[J].Journal of Tsinghua University(Science and Technology),1997(2).
Authors:Tang Hong  Yang Ruichang  Lu Zhongqi  Shi Deqiang  Feng Junkai
Institution:Tang Hong,Yang Ruichang,Lu Zhongqi,Shi Deqiang,Feng Junkai Department of Thermal Engineering,Tsinghua University,Beijing 100084
Abstract:The safety analysis of water walls of a 300 MW once through boiler in peak load operation was introduced. The boiler made in China is taking peak load operation, with quick variation of its loads. The authors analyzed the influence of deviation of combustion center on the safety of water walls at varying loads, including the deviation of heat absorption of water wall tubes at 300 MW, 260 MW, 240 MW and 210 MW. With the help of electronic computer, the deviations of flow rates in water wall tubes and the relevant tube wall temperatures were obtained. From the data collected, the condition of burn out, or rupture of water wall tubes was obtained. Besides, the allowable deviation of combustion center was obtained. Thus, the measures to prevent tubes from burn out were obtained, the measures to make the boiler operate safely and reliably were also obtained.
Keywords:once  through boiler  peak load  burn out of water wall tubes  analysis