火电站哈蒙系统空冷器的热力计算
引用本文:刘宝兴. 火电站哈蒙系统空冷器的热力计算[J]. 上海理工大学学报, 1992, 0(3)
作者姓名:刘宝兴
摘    要:
本文提出空冷电站哈蒙系统的空冷器和自然通风冷却塔的热力计算方法。以600 MW机组为例的计算结果与实际数值极为吻合。

关 键 词:间接空冷  表面式凝汽器  椭圆绕片管  自然通风冷却塔

ON THERMAL CALCULATION OF THE HARMON SYSTEM AND ITS AIR COOLER FOR POWER PLANTS
Liu Baoxing. ON THERMAL CALCULATION OF THE HARMON SYSTEM AND ITS AIR COOLER FOR POWER PLANTS[J]. Journal of University of Shanghai For Science and Technology, 1992, 0(3)
Authors:Liu Baoxing
Affiliation:Liu Baoxing
Abstract:
This article reviews the structure and features of Harmon's indirect air cooling system. Taking a 600MW air cooled unit as an example, the thermodynamic calculation of air cooled heat exchanger assembly and dry cooling lower has been elucidated. Good agreement is found between the computed results and the existing data.
Keywords:Indirect air cooling  Surface condenser  Elliptical spiral fin tube  Natural draugght tower