摘    要:通过对输电线路杆塔接地电阻偏高的现象进行分析,结合工程实例,从设计、施工、运行等方面入手,提出了切实可行的措施,以达到降低杆塔接地电阻的目的.

关 键 词:输电线路  接地装置  降阻措施

Study on the Measures for Lowering Effectively the Grounding Resistance of the Transmission Line Tower
ZHANG Hui-zhong,XU Zhi-yong.Study on the Measures for Lowering Effectively the Grounding Resistance of the Transmission Line Tower[J].Sci-Tech Information Development & Economy,2009,19(18):165-167.
Authors:ZHANG Hui-zhong  XU Zhi-yong
Abstract:Through an analysis on the phenomenon of that the grounding resistance of the transmission lines tower is higher, and connecting with the engineering project, this paper puts forward some measures for lowering the grounding resistance of the transmission lines tower from aspects of the design, construction, and operation, etc.