首页 | 本学科首页   官方微博 | 高级检索  
     

Enantioselective assay of S(+)- and R(-)-propafenone in human urine by using RP-HPLC with pre-column chiral derlvatization
引用本文:Wu YJ,Ma MM,Zheng S. Enantioselective assay of S(+)- and R(-)-propafenone in human urine by using RP-HPLC with pre-column chiral derlvatization[J]. 浙江大学学报(自然科学英文版), 2004, 5(2): 226-229
作者姓名:Wu YJ  Ma MM  Zheng S
摘    要:

关 键 词:丙胺苯丙酮 尿液 手性衍生作用 冰醋酸 药物动力学

Enantioselective assay of S+ - and R- -propafenone in human urine by using RP-HPLC with pre-column chiral derivatization
Wu Yong-jiang,Ma Ming-ming,Zheng Su. Enantioselective assay of S+ - and R- -propafenone in human urine by using RP-HPLC with pre-column chiral derivatization[J]. Journal of Zhejiang University Science, 2004, 5(2): 226-229
Authors:Wu Yong-jiang  Ma Ming-ming  Zheng Su
Affiliation:College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310031, China.
Abstract:The enantioselective assay for S(+)- and R(-)-propafenone (PPF) in human urine that developed in this work involves extraction of propafenone from human urine and using S(+)-propafenone as internal standard, chiral derivatization with 2,3,4,6-tetra-O-beta-D-glucopranosyl isothiocyanate, and quantitation by an RP-HPLC system with UV detection (lambda=220 nm). A baseline separation of propafenone enantiomers was achieved on a 5-microm reverse phase ODS column, with a mixture of acetic acid (25:12:0.02,v/v) as mobile phase. There was good linear relationship from 24.9 ng/ml to 1875.0 ng/ml for both of enantiomers. The regression equations of the standard curves based on C(S-PPF) (or C(R-PPF)) versus ratio of A(S-PPF)/A(S) (or A(R-PPF)/A(S)) were y=0.0032x-0.081, (r=0.999) for S-PPF and y=0.0033x+0.0039, (r=0.998) for R-PPF, respectively. The method's limit of detection was 12.5 ng/ml for both enantiomers, and the method's limit of quantitation was 28.2+/-0.52 ng/ml for S-PPF, 30.4+/-methanol:water:glacial 0.53 ng/ml for R-PPF (RSD<8%, n=5). The analytical method yielded average recovery of 98.9% and 100.4% for S-PPF and R-PPF, respectively. The relative standard deviation was no more than 6.11% and 6.22% for S-PPF and R-PPF, respectively. The method enabled study of metabolism of S(+)- and R(-)-propafenone in human urine. The results from 7 volunteers administered 150 mg racemic propafenone indicated that propafenone enantiomers undergo stereoselective metabolism and that in the human body, S(+)-propafenone is metabolized more extensively than R(-)-propafenone.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号