首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高压电缆护层故障测距新方法
引用本文:徐丙垠.高压电缆护层故障测距新方法[J].山东理工大学学报,1999(3).
作者姓名:徐丙垠
作者单位:山东工程学院科学技术研究院
摘    要:35KV以上高压单芯电缆护层绝缘破坏是一种比较常见的故障现象,目前的护层故障测距方法精度受导引线及接触电阻影响比较大.本文提出了测量电缆护层端头与故障点之间电阻的故障精确测距方法,介绍了新的测距方法实际使用中的几个问题,该方法具有测量精度高,简单、实用的优点.

关 键 词:电力电缆  护层  故障测距

An Accurate Cable Sheath Fault Distance Measurement Method
Xu Bingyin.An Accurate Cable Sheath Fault Distance Measurement Method[J].Journal of Shandong University of Technology:Science and Technology,1999(3).
Authors:Xu Bingyin
Institution:Insitute of Science and Technology
Abstract:Sheath insulation damage is a very common fault type of single phase HV power cable. Accuracy of the existing sheath fault distance measurement methods is subject to test lead and contact resistance influence, and therefore is not satisfactory for practical fault location application. A new distance measurement method of cable sheath fault is introduced in this paper. It measures resistance of cable sheath between terminal and fault point. The proposed method is free from influence of test lead and contact resistance, simple and practically applicable.
Keywords:cable  sheath  fault location  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号