摘    要:在负压大的烟道中采集烟气时,由于现用采样泵的流速小于烟气流速而出现倒吸或采不到完整样品的现象,通过多次现场实验和理论分析,设计组装了简便的烟气采样辅助设备,解决了上述问题.

关 键 词:固定污染源  负压  倒吸  烟气  辅助设备

On Sampling the Fumes at Fixed Pollution Sources
CHEN Wei,YANG Dong-hua,MA Li.On Sampling the Fumes at Fixed Pollution Sources[J].Journal of Gansu Sciences,2011,23(4):54-57.
Authors:CHEN Wei  YANG Dong-hua  MA Li
Institution:CHEN Wei,YANG Dong-hua,MA Li(Jiayuguan Station of Environmental Monitoring,Jiayuguan 735100,China)
Abstract:As the sampling speed is often smaller than the speed of emission in the channels under negative pressures,suck-back will occur,then qon cannot get perfect samples.To solve these problems,we have designed a set of accessory equipment which is simple and easy to handle.