首页 | 本学科首页   官方微博 | 高级检索  
     检索      

精密的低频相位校准标准
引用本文:乐伟达,胡新国,陈桂芳.精密的低频相位校准标准[J].应用科学学报,1985,3(4):336-340.
作者姓名:乐伟达  胡新国  陈桂芳
作者单位:上海测试技术研究所
摘    要:一种新型高精密低频相位校准标准已研制成功,它采用相位误差倍减技术,在20Hz~100kHz (点频)内,相移量范围是0~n×360°(n是整数),准确度为±(1×10-6×F±0.001)度,F为工作频率,单位为Hz.相移量分辨率为(3×10-8×F)度.输出信号实测的失真度优于1×10-4,幅度稳定度优于1×10-5/10min.

收稿时间:1982-12-20
修稿时间:1984-06-20

PRECISION LOW FREQUENCY PHASE CALIBRATION STANDARD
LO WEIDA,HU XINGUO,CHENG GUEIFAN.PRECISION LOW FREQUENCY PHASE CALIBRATION STANDARD[J].Journal of Applied Sciences,1985,3(4):336-340.
Authors:LO WEIDA  HU XINGUO  CHENG GUEIFAN
Institution:Shanghai Institute Of Testing Technology
Abstract:A new high-precision low frequency phase calibration standard has been developed by using a technique of phase error demultiplication. The frequency range is from 20 Hz to 100 kHz (discrete frequency). The phase shift is from 0 to (n×360) degrees, where n is an integer. Theresolution is (3×10-8×F) degrees, where F is in hertz. The accuracy is ±(1×10×F±0.001) degrees. The distortion is better than 1×10-5/10min.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《应用科学学报》浏览原始摘要信息
点击此处可从《应用科学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号