首页 | 本学科首页   官方微博 | 高级检索  
     

Parallel imaging methods for phased array MRI
引用本文:ZHANG Bida,WANG Weidong,SONG Xiaoyu,ZU Donglin,CHEN Guangfei and BAO Shanglian(1. Institute of Heavy Ion Physics,the Research Center for Tumor Diagnosis and Therapeutical Physics,the Beijing Key Laboratory of Medical Physics & Engineering,Peking University,Beijing 100871,China, 2. General Hospital of PLA,Beijing 100085,China). Parallel imaging methods for phased array MRI[J]. 自然科学进展(英文版), 2003, 13(4)
作者姓名:ZHANG Bida  WANG Weidong  SONG Xiaoyu  ZU Donglin  CHEN Guangfei and BAO Shanglian(1. Institute of Heavy Ion Physics  the Research Center for Tumor Diagnosis and Therapeutical Physics  the Beijing Key Laboratory of Medical Physics & Engineering  Peking University  Beijing 100871  China   2. General Hospital of PLA  Beijing 100085  China)
作者单位:1. Institute of Heavy Ion Physics,the Research Center for Tumor Diagnosis and Therapeutical Physics,the Beijing Key Laboratory of Medical Physics & Engineering,Peking University,Beijing 100871,China; 2. General Hospital of PLA,Beijing 100085,China
基金项目:Supported by the National Natural Science Foundation of Beijing (Grant No. 3011002) and the Key Program of the Tenth Five-Year Plan of the Ministry of Science and Technology (2001BA706B02)
摘    要:Two parallel methods for magnetic resonance tmaging (MRI) using radio frequency (RF) phased array surface coiks, named spatial loca! Fourier encoding (SLFE) and spatial RF encoding (SRFE), are presented. The MR signals are acquired from separate channels across the coils, each of which covers a sub-FOV (field-of-view) in a parallel fashion, and the acquired data are combined to form an image of entire FOV. These two parallel encoding techniques can accelerate MR imaging greatly, yet associated artifact rnay appear, al-though the SLFE is an effective image reconstruction method which can reduce the localized artifact in some degrees. By the SRFE, RF coil array can be utilized for spatial encoding through a specialized coil design. The images are acquired in a snapshot with a high signal-to-noise ratio (SNR) without the costly gradient system, resulting in great saving of cost. Both mutual induction and aliasing effect of adja-cent coils are critical to the success of SRFE. The strategies of inverse sourc


Parallel imaging methods for phased array MRI
ZHANG Bida,WANG Weidong,Song Xiaoyu,ZU Donglin,Chen Guangfei,Bao Shanglian. Parallel imaging methods for phased array MRI[J]. Progress in Natural Science, 2003, 13(4)
Authors:ZHANG Bida  WANG Weidong  Song Xiaoyu  ZU Donglin  Chen Guangfei  Bao Shanglian
Abstract:Two parallel methods for magnetic resonance tmaging (MRI) using radio frequency (RF) phased array surface coiks, named spatial loca! Fourier encoding (SLFE) and spatial RF encoding (SRFE), are presented. The MR signals are acquired from separate channels across the coils, each of which covers a sub-FOV (field-of-view) in a parallel fashion, and the acquired data are combined to form an image of entire FOV. These two parallel encoding techniques can accelerate MR imaging greatly, yet associated artifact rnay appear, al-though the SLFE is an effective image reconstruction method which can reduce the localized artifact in some degrees. By the SRFE, RF coil array can be utilized for spatial encoding through a specialized coil design. The images are acquired in a snapshot with a high signal-to-noise ratio (SNR) without the costly gradient system, resulting in great saving of cost. Both mutual induction and aliasing effect of adja-cent coils are critical to the success of SRFE. The strategies of inverse source problem and wavelet transform (WT) can be employed to e-Hminate them. The results simulated by MATLAB are reported.
Keywords:MRI   radiofrequency   phased-array.
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号