首页 | 本学科首页   官方微博 | 高级检索  
     检索      

IC+SBR处理抗生素废水脱氮效果研究
引用本文:王爱芹,买文宁,余杰.IC+SBR处理抗生素废水脱氮效果研究[J].河南科学,2007,25(6):1052-1054.
作者姓名:王爱芹  买文宁  余杰
作者单位:郑州大学,环境与水利学院,郑州,450002
摘    要:采用IC+SBR组合工艺处理高浓度抗生素废水,结果表明,抗生素废水进入IC反应器后,得到有效的水解发酵,将有机氮充分转化为氨氮,厌氧出水经过SBR反应器处理后出水氨氮质量浓度降低到30 mg/L,有时甚至在20 mg/L以下,去除率高达80%,出水水质良好.

关 键 词:内循环厌氧反应器  间歇式活性污泥法  抗生素废水  氨氮
文章编号:1004-3918(2007)06-1052-03
修稿时间:2007-06-08

Study of Removing Ammonia-nitrogen Using IC+SBR in Treating Antibiotic Wastewater
WANG Ai-qin,MAI Wen-ning,YU Jie.Study of Removing Ammonia-nitrogen Using IC+SBR in Treating Antibiotic Wastewater[J].Henan Science,2007,25(6):1052-1054.
Authors:WANG Ai-qin  MAI Wen-ning  YU Jie
Abstract:Antibiotic wastewater is treated by the combined IC SBR technique in this test,the conclusion demonstrates: the organic nitrogen compound in antibiotic wastewater is degraded into ammonia-nitrogen effectively in the IC reactor.The ammonia-nitrogen concentration in treated wastewater from SBR reactor is 30 mg / L,sometimes the concentration is below 20 mg / L,the ammonia-nitrogen removal rate is up to 80 % and the quality of effluent is very well.
Keywords:internal circulation reactor  sequencing batch reactor  antibiotic wastewater  ammonia-nitrogen  
本文献已被 CNKI 维普 万方数据 等数据库收录!