摘    要:对我国双线电气化铁道区段接触网V形天窗停电作业中影响作业安全的感应电压进行了分析,说明在V形天窗作业时感应电压对检修人员的人身安全构成威胁,提出了可行的预防感应电压触电事故的措施,为牵引供电系统安全运行和维护提供了借鉴。

关 键 词:接触网  V形天窗  停电作业  感应电压  触电事故  预防措施

Analysis on the Induced Voltage in Power Cut Operation of Overhead Contact System's V-Shaped Skylight
LI Huijie.Analysis on the Induced Voltage in Power Cut Operation of Overhead Contact System's V-Shaped Skylight[J].Shanxi Science and Technology,2014(4):75-78.
Authors:LI Huijie
Abstract:This paper analyzes the induced voltage of V-shaped skylight of overhead contact system in China's double electrified railway sections in power cut operation influencing the operation safety,explains that the induced voltage in the operation on V-shaped skylight will probably pose a threat to the personal safety of maintenance personnel,and puts forward some feasible measures for preventing the electric shock caused by the induced voltage,providing the reference for the safe operation and maintenance of tractive power supply system.
Keywords:overhead contact system  V-shaped skylight  power cut operation  induced voltage  electric shock  preventive measures