首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 48 毫秒
1.
采用控制电位电解法,在玻碳电极((GCE)上进行石墨烯(GN)/壳聚糖(CS)修饰膜的电沉积,将制得的膜修饰电极GN/CS/GCE在0.1 mol·L-1的HAc-NaAc电解液(pH=4.2)于-0.5 V(vs.SCE)电位下富集Cu2+,并用差分脉冲溶出伏安法测定.结果表明,该膜修饰电极对Cu2+的富集作用明显强于裸GCE及CS/GCE.在优化实验条件下,Cu2+的浓度在1.0~80.0μmol·L-1范围内与阳极溶出峰电流呈线性关系,相关系数为0.999 6,检出限为12.66 nmol·L-1,所制得的修饰电极具有较高的灵敏度和选择性.  相似文献   

2.
采用Hummers法制备还原石墨烯,用滴加法将石墨烯修饰到玻碳电极表面,考察了石墨烯修饰层数、底液pH、富集时间和富集电位对铅离子检测的影响,并选定最佳条件.用线性伏安法在最佳条件下检测溶液中的铅离子,结果表明铅离子的溶出峰电流与其浓度的对数在5×10-6mol/L~8×10-5 mol/L范围内呈良好的线性关系,检测限为3.6×10-7 mol/L.石墨烯/玻碳电极也表现出良好的稳定性、重现性和抗干扰能力,并可用于实际水样的检测.  相似文献   

3.
4.
以丁二酮肟作为修饰剂制备化学修饰电极,用于痕量镉的伏安法测定.研究了支持电解质种类及酸度、修饰膜厚度、富集电位、富集时间、扫描速度等因素对伏安曲线的影响,获得较为优化的测试条件,在0.1mo/L HAc—NaAc缓冲溶液(pH=4.0)中,ca(Ⅱ)的浓度在2.0×10^-9moL/L-2.0×10^-6 moL/L范围内与它的氧化峰电流呈良好线性关系,检测限达2.0×10^-9 moL/L.该电极具有很好的重现性.在含4.0×10^-7moL/Lcd(n)试液中连续测定10次,其RSD为7.8%.本法用于环境污水样(咸宁市咸安区的西河水)测定,获得满意的结果.  相似文献   

5.
提出了一种新颖的同位镀铋膜过氧化聚乙酰苯胺修饰的玻碳电极(Bi/over-oxidized PNAANI/GCE)方波溶出伏安法(SWASV)同时检测食用盐中Cd(Ⅱ)和Pb(Ⅱ)的方法.过氧化聚乙酰苯胺膜具有良好的阳离子选择通透性,大大改善了修饰电极检测重金属时的灵敏度和选择性.同位镀铋膜可以作为汞膜的替代物,用于提高修饰电极对Cd(Ⅱ)和Pb(Ⅱ)的富集能力.Cd(Ⅱ)和Pb(Ⅱ)的分析曲线均覆盖了两个线性范围:0.2~3.0μg·L-1和3.0~33μg·L-1,在富集时间为300s时,Cd(Ⅱ)和Pb(Ⅱ)检测限分别为0.015μg·L-1和0.029μg·L-1.此外,这种修饰电极还具有很高的稳定性和抗干扰性能.最后,该修饰电极被成功地应用于食用盐样品中Cd(Ⅱ)和Pb(Ⅱ)的同时测定.  相似文献   

6.
采用阳极溶出伏安法,以铋膜电极替代汞膜电极测定水样中痕量铅和镉离子。考察并优化了同位镀铋膜测定铅、镉的条件。实验结果表明:铅和镉在铋膜电极上可得到灵敏的溶出峰,峰高和溶出电位与汞膜电极法相近,使用铋膜电极可避免使用汞膜电极带来的环境污染。当电沉积时间为5min时,铅和镉的检出限分别达1.0×10^-7moL/L和5.0×10^-8mol/L。同时,由于每次溶出后可方便地将铋膜溶解更新,因此,能保证各次测定的重现性。  相似文献   

7.
采用汞膜玻碳电极阳极溶出伏安法测定墨鱼干、大米和西红柿中的痕量镉和铅.样品先于500℃灰化,继用少量1:1HNO3+H2O2消解,不经任何分离,可直接进行测定,Cd2+和Pb2+的浓度分别低至0.10μg·L-1和0.20μg·L-1时仍能检出.  相似文献   

8.
采用银纳米颗粒(AgNPs)和还原氧化石墨烯(RGO)制备成AgNPs/RGO复合物;并且用这种复合物修饰玻碳电极(GCE),制备出来的电化学传感器对对硝基苯酚(4-NP)进行微量检测。在最优的情况下,对4-NP的线性响应范围是0.005~5μmol/L和10~100μmol/L,检测限是5.28 nmol/L。由于该传感器具有比较宽的检测范围、令人满意的稳定性、特别低的检测限,所以这种电化学传感器可以应用到工业和生活当中,具有很好的应用前景。  相似文献   

9.
10.
8—羟基喹啉修饰玻碳电极阳极溶出伏安法测定痕量镉   总被引:3,自引:0,他引:3  
以8-羟基喹啉(Ox)作为修饰剂制备化学修饰电极,用于痕量镉的伏安法测定.研究了支持电解质种类及酸度、修饰膜厚度、富集电位、富集时间、扫描速度等因素对伏安曲线的影响,获得较为优化的测试条件.在0.1mol/LHAc-NaAc缓冲溶液(pH4.0)中,Cd(Ⅱ)的浓度在4.0×10-8mol/L~7.0×10-5mol/L范围内与其氧化峰电流呈良好线性关系(r=0.9933),检测限达2.0×10-8mol/L.该电极具有很好的重现性,在含2.0×10-6mol/LCd(Ⅱ)试液中连续测定10次,其RSD为7.8%.本法用于实际水样测定,获得满意的结果.  相似文献   

11.
用F—78脉冲极谱仪,以玻碳汞膜电极为工作电极,选择0.1MNaAc—0.1MHAc—0.1MKCl作底液,对饮水中痕量镉进行阳极溶出伏安测定。研究了影响镉溶出峰电流大小的各种因素,确定了测定饮水中镉的最佳条件。对贵州大学饮水的测定结果表明:平均镉含量<1×10~(-4)μg.ml~(-1),远低于我国“地面水环境质量一级标准”的规定。(镉含量≤1ppb)  相似文献   

12.
以强碱型阴离子交换树脂为吸附剂,以2.5 mol/L HCl为络合剂,去离子水为洗脱液,对铅、镉和锌进行了静态阴离子交换分离富集,提高了在0.03 mol/L HClO4底液中微分阳极溶出伏安法同时测定铅、镉和锌的灵敏度,减少了基体干扰.此法应用于食品中Pb,Cd和Zn的同时测定,回收率分别为91%~95%,93%~97%,89%~93%,相对标准偏差(n=9)分别为1.72%,1.38%,1.96%,获得了较好的结果.  相似文献   

13.
An electrochemical method for the simultaneous determination of lead(II) and Cadmium(II) with a calix[6]arene modified carbon paste electrode (CPE) has been developed. Pb2+ and Cd2+ were accumulated at the surface of the modified electrode via formation of chemical complexes with calix[6]arene, and reduced at 1.40 V. During the following anodic potential sweep, reduced lead and cadmium were oxidized, and two well-defined striping peaks appeared at about −0.60 V and −0.84 V. Compared with a bare carbon paste electrode, the calix[6]arene modified CPE greatly improves the sensitivity of determining lead and cadmium. The stripping peak currents change linearly with the concentration of Pb2+ 3.0×10−8–8.0×10−6 mol·L−1 and with that of Cd2+ 6.0×10−8–1.0×10−5 mol ·L−1. The detection limits of Pb2+ and Cd2+ are found to be 8.0×10−9 mol·L−1 and 2.0×10−8 mol·L−1, respectively. The modified carbon paste electrode was applied to determine trace levels of lead and cadmium in water samples. Comparing with that of atomic absorption spectrometry, the results suggests that the calix[6]arene modified CPE has great potential for the practical sample analysis. Foundation item: Supported by the National Natural Science Foundation of China (60171023) Biography: JI Xiao-bo (1980-), male, Master, research direction: electroanalytical chemistry.  相似文献   

14.
介绍阳极溶出伏安法的基本原理、基本流程,利用汞膜电极对有色金属矿区雨水径流中铅和镉中重金属元素同时进行测定,并将所测得的结果进行传输保存;在选定的最佳实验条件下,测得雨水径流中镉、铅相对标准偏差分别为0.200%和0.287%,回收率均在89.5%到105%之间,取得比较理想的测定结果.  相似文献   

15.
采用HNO3-H2O2消解-电化学方法测定小米中的铬含量。在DTPA-HAc-Na Ac体系中铬(Ⅵ)离子在镀汞电极上形成汞齐从而得到氧化峰电流,考察能够满足电化学测定的前处理消解技术。结果表明,铬(Ⅵ)离子的消解液在温度130℃,硝酸10 m L,过氧化氢38 m L,p H值呈中性时能够得到很好的电化学测定结果,线性相关系数为0.99,回收率为90%~110%。方法可以用于米中痕量铬(Ⅵ)的测定。  相似文献   

16.
为实现玻碳电极在电化学传感器领域的高灵敏度检测利用, 在pH=5.0的磷酸盐缓冲溶液中, 用恒电位法对玻碳电极进行电化学活化,考察pH值、富集电位及富集时间对Pb2+检测效果的影响, 并研究最佳实验条件下的活化电极对Pb2+的检测性能. 实验结果表明:该活化电极对Pb2+的电化学检测响应电流具有增强效果,并具有检测时间短、灵敏度高的特点;检测线性范围为1×10-10~ 5×10-6 mol/L,最低检出限和定量限分别为3×10-11 mol/L和1.0×10-10 mol/L. 该活化电极在自来水Pb2+的测定中具有较高回收率, 可用于实际水质检测.  相似文献   

17.
将铋和聚苯胺共沉积在玻碳电极上制备了杂化膜,然后在杂化膜上沉积一层铋膜,制备了一种新颖的电化学传感器——有机-无机杂化复合铋膜电极(HCBiFE),用于痕量重金属离子Cd(Ⅱ)和Pb(Ⅱ)的检测(0.1mol/L醋酸缓冲溶液,pH 4.7).优化了镀膜条件、离子测试参数.在1~90 μg·L-1的浓度范围内,两离子溶出峰电流与浓度呈现出良好的线性关系,富集时间120 s时,Cd(Ⅱ)和Pb(Ⅱ)的检测限分别低至0.2,0.5μg·L-1.该复合膜具有很好的稳定性和重现性,能够抗机械剥蚀、不易脱落,对50 μg·L-1的Cd(Ⅱ)和Pb(Ⅱ)连续测定50次,相对标准偏差分别为4.3%,6.1%.30 d后,该复合膜电极对Cd(Ⅱ)和Pb(Ⅱ)溶出峰电流分别下降3.2%,4.9%,表明该复合膜电极性能稳定,有望应用于环境水体的现场监测.  相似文献   

18.
用差分脉冲伏安法研究了甘草酸(GA)在ITO玻璃电极上的电化学行为,发现其氧化峰电流值与甘草酸的浓度在一定范围内(0.5×10-3g·L-1~1.0×10-3g·L-1)成正比列关系,检测限为0.02 mg·L-1,且甘草提取物中的主要成分如甘草类黄酮以及一些无机离子等不会干扰测定的结果。通过研究能建立一种快速准确的测定甘草提取物中甘草酸含量新的方法。  相似文献   

19.
以浸入沉积的方法在硅纳米线上修饰了金纳米颗粒,并通过电子扫描显微镜(SEM)和X射线荧光分析(XRF)对金纳米粒子修饰的硅纳米线电极表面形貌进行了表征.以修饰后的硅纳米线电极作为工作电极,采用阳极溶出法检测水中痕量铅和铜,考察pH值、富集电位和富集时间对溶出峰的影响,优化出最佳实验条件.在优化的实验条件下,铅Pb2+和铜Cu2+的灵敏度分别为0.649μA/(μg.L-1)和0.177μA/(μg.L-1).检测极限达到0.26μg.L-1和0.67μg.L-1.峰电流与离子浓度在质量浓度25~200μg.L-1的范围内形成良好的线性关系.  相似文献   