The model of coil heat dissipation of low-temperature hot water floor radiation with the covering materials has been established, and the influences of coil heat dissipation of low-temperature hot water floor radiation at the different dimensions of covering materials were simulated. The results show that: (1) the increase of covering materials areas can cause the local floor temperature to rise at a certain extent of covering materials. (2) at a certain extent of the covering materials, the increase of covering materials areas is directly proportional to the decrease of the floor heat dissipation, but the influences of coil heat dissipation of low-temperature hot water floor radiation have not been obviously by increasing of covering materials areas
参考文献
相似文献
引证文献
引用本文
贾明岩. 覆盖物对低温热水地板辐射盘管散热影响分析[J]. 科学技术与工程, 2011, (5): . Jia Mingyan. Influence Analysis of Covering Materials on Coil Heat Dissipation of Low-Temperature Hot Water Floor Radiation[J]. Science Technology and Engineering,2011,(5).