Abstract:In the reinforced concrete building continuous vibration resistance wall structure is analyzed, using traditional methods need to a lot of experimental data regression analysis, a lot of work.Put forward a new kind of reinforced concrete building continuous vibration resistance wall structure analysis method.Choose five layer building wall structure of reinforced concrete frame, the total information, materials information structure and load information.Determined by building wall structure finite element model of concrete material, reinforced material attribute and cross section and the unit materials.Through the analysis of reinforced concrete building continuous vibration wall structure are continuous collapse resistance, found by analysis of reinforced concrete buildings collapsed wall structure there will be no continuity.Removed by analyzing the structure of column of reinforced concrete building structure internal force of continuous vibration resistance wall, found after remove inner cylinder wall structure collapsed there will be no continuity, there will be no column shear, bending failure;Remove Angle and long after the side in the column, wall board will lose support structure in large part, to the shear bearing capacity and flexural bearing capacity of the column.